Kidde Battery Operated Wireless Interconnect Smoke Alarm
RF-SM-DC
Enables quick and easy installation of an interconnected smoke alarm system without messy wiring or labor
-
When one alarm sounds, they all do: wireless technology uses radio frequency to both transmit and receive messages about a hazard in the home.
-
Battery power enables homeowners to install interconnected alarms without rewiring.
-
Smart touch button quickly and temporarily silences nuisance alarms.
-
Wireless alarm can be installed in a detached workshop or shed.
-
Kidde wireless smoke alarms meet UL requirements.
-
Model #: 0919-9999
The Kidde Wireless Battery Powered Smoke Alarm allows for the easy installation of an interconnected smoke alarm system without the high cost and hassle of rewiring your home. The alarms are wirelessly linked so that when one alarm is triggered, all alarms will sound. This alarm can also be placed in a detached workshop or shed and linked into the home's interconnected system.
Experts recommend interconnected alarms, because when one sounds, they all sound, providing an early warning against fire by dramatically increasing your ability to hear an alarm anywhere in your home, regardless of where the fire starts. Newer homes are required by code to have interconnected alarms. Wireless technology now enables any home to have an interconnected system.
Choose the Right Wireless Alarms for Your Home. Kidde offers two wireless product options: a Battery Powered Smoke Alarm, and an AC Powered Smoke Alarm. These products enable you to customize your system based on your specific needs. Read below to see which Kidde wireless smoke alarms are best for your home.
Kidde Wireless Smoke Alarms enable you to extend the coverage and protection of interconnected smoke alarms —without any need for additional wiring! This alarm uses ionization sensing technology. Ionization sensing alarms may detect invisible fire particles (associated with flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible particles (associated with smoldering fires) sooner than ionization alarms.
Kidde strongly recommends that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fire that can occur within the home.
Part Number(Ordering Number):0919-9999
-
Hush® Feature – Temporarily silences nuisance alarms.
-
Flashing LED – Indicates alarm is receiving power.
-
Test Button – Verifies battery and alarm operation.
-
Battery Operated (batteries included) – Protects even during power outages.
-
Tamper Resist Locking Pin – Helps deter from theft or tampering.
-
Low Battery Indicator – Smoke alarm will chirp in the event of a low battery.
-
Twist-Off Mounting – For fast installation and easy, safe battery replacement.
Technical Specifications
Power Source: | 3 AA batteries |
Audio Alarm: | 85dB at 10ft |
Temperature Range: | 40F (4.4C) to 100F (37.8C) |
Humidity Range: | up to 85% relative humidity (RH) |
Sensor: | Ionization |
Wiring: | None |
Size: | 5.75” in diameter x 1.25” depth |
Weight: | .5lb |
Interconnects: | Up to 24 devices ( of which 18 can be initiating) |
Architectural and Engineering Specifications
The smoke alarm shall be Kidde Model RF-SM-DC or approved equal. It shall be powered by three (3) AA batteries. The unit shall incorporate an ionization sensor with nominal sensitivity of 0.69±0.19%/ft. The temperature operation range shall be between 40F (4C) to 100F (38C) and the humidity operating range shall be up to 85% relative humidity. The smoke alarm shall work interconnected immediately out of the box without any user programming. A maximum of 24 Kidde devices can be interconnected in a multiple station arrangement. The interconnect system must not exceed the NFPA (National Fire Protection Association) limit of 18 initiation devices, of which 12 can be smoke alarms. With 18 initiating devices (smoke, heat, CO, etc.), interconnected, it is still possible to interconnect 6 strobe lights and or relay modules. The smoke alarm shall give fire alarm signals priority over all other signals. The smoke alarm shall incorporate a maximum allowable response delay from activation of an initiating device to receipt and alarm/display by the receiver/control unit of 30 seconds. The smoke alarm shall automatically repeat alarm transmission at intervals not exceeding 60 seconds until the initiating device is returned to its non-alarm condition (per NFPA 72, Chapter 6, Section 6.16.3.2). The smoke alarm shall have remote hush and low battery hush capabilities. The unit shall have alarm memory to indicate which alarm in a system was the initiating alarm (per NFPA 72, Chapter 6, Section 6.16.3.5). The unit shall provide optional tamper resistance that deters removal of the unit from the wall or ceiling. The alarm shall include a test button that will electronically simulate the presence of smoke and cause the unit to go into alarm. This sequence tests the unit’s electronics, battery and horn to ensure proper operation. The unit shall include a piezoelectric horn that is rated at 85 decibels at 10 feet. The smoke alarm shall produce an audible signal in the form of the “three pulse” temporal pattern. Each ON phase shall last 0.5-second +/-10 percent. After the third of these ON phases, there shall be an OFF phase that lasts 1.5 seconds +/-10 percent. This pattern should repeat continuously without interruption. The unit shall also include a low battery warning utilizing a brief alarm chirp every 30-40 seconds for a minimum of seven (7) days. The unit shall incorporate one red LED to indicate the alarm’s current status and mode of operation. The red LED will flash in conjunction with the alarm beep, and flash during a smoke alarm, a low battery mode and a unit error. The unit shall incorporate one green LED to indicate the alarm’s current status and mode of operation. The green LED will indicate one of four (4) conditions: Standby Condition – The LED will flash approximately every 10 seconds. Initiating Alarm Indicator – The LED will flash every second while sounding an alarm to signify that the alarm sensed a smoke hazard. Alarm Memory Condition – The LED will flash every second signifying that the alarm sensed a smoke hazard. It will continue to flash every second until the test/reset button is pressed, thus resetting the alarm. Hush® Mode Condition – The LED will flash every 2 seconds while the alarm is in Hush® Mode The unit shall at a minimum meet the requirements of UL217, NFPA72 (chapter 11 2002 edition), The State of California Fire Marshall, NFPA 101 (one and two family dwellings) Federal Housing Authority (FHA), Housing and Urban Development (HUD). It shall also include a 10-year manufacturer’s limited warranty.
The Kidde Wireless Battery Powered Smoke Alarm allows for the easy installation of an interconnected smoke alarm system without the high cost and hassle of rewiring your home. The alarms are wirelessly linked so that when one alarm is triggered, all alarms will sound. This alarm can also be placed in a detached workshop or shed and linked into the home's interconnected system.
Experts recommend interconnected alarms, because when one sounds, they all sound, providing an early warning against fire by dramatically increasing your ability to hear an alarm anywhere in your home, regardless of where the fire starts. Newer homes are required by code to have interconnected alarms. Wireless technology now enables any home to have an interconnected system.
Choose the Right Wireless Alarms for Your Home. Kidde offers two wireless product options: a Battery Powered Smoke Alarm, and an AC Powered Smoke Alarm. These products enable you to customize your system based on your specific needs. Read below to see which Kidde wireless smoke alarms are best for your home.
Kidde Wireless Smoke Alarms enable you to extend the coverage and protection of interconnected smoke alarms —without any need for additional wiring! This alarm uses ionization sensing technology. Ionization sensing alarms may detect invisible fire particles (associated with flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible particles (associated with smoldering fires) sooner than ionization alarms.
Kidde strongly recommends that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fire that can occur within the home.
Part Number(Ordering Number):0919-9999
-
Hush® Feature – Temporarily silences nuisance alarms.
-
Flashing LED – Indicates alarm is receiving power.
-
Test Button – Verifies battery and alarm operation.
-
Battery Operated (batteries included) – Protects even during power outages.
-
Tamper Resist Locking Pin – Helps deter from theft or tampering.
-
Low Battery Indicator – Smoke alarm will chirp in the event of a low battery.
-
Twist-Off Mounting – For fast installation and easy, safe battery replacement.
Technical Specifications
Power Source: | 3 AA batteries |
Audio Alarm: | 85dB at 10ft |
Temperature Range: | 40F (4.4C) to 100F (37.8C) |
Humidity Range: | up to 85% relative humidity (RH) |
Sensor: | Ionization |
Wiring: | None |
Size: | 5.75” in diameter x 1.25” depth |
Weight: | .5lb |
Interconnects: | Up to 24 devices ( of which 18 can be initiating) |
Architectural and Engineering Specifications
The smoke alarm shall be Kidde Model RF-SM-DC or approved equal. It shall be powered by three (3) AA batteries. The unit shall incorporate an ionization sensor with nominal sensitivity of 0.69±0.19%/ft. The temperature operation range shall be between 40F (4C) to 100F (38C) and the humidity operating range shall be up to 85% relative humidity. The smoke alarm shall work interconnected immediately out of the box without any user programming. A maximum of 24 Kidde devices can be interconnected in a multiple station arrangement. The interconnect system must not exceed the NFPA (National Fire Protection Association) limit of 18 initiation devices, of which 12 can be smoke alarms. With 18 initiating devices (smoke, heat, CO, etc.), interconnected, it is still possible to interconnect 6 strobe lights and or relay modules. The smoke alarm shall give fire alarm signals priority over all other signals. The smoke alarm shall incorporate a maximum allowable response delay from activation of an initiating device to receipt and alarm/display by the receiver/control unit of 30 seconds. The smoke alarm shall automatically repeat alarm transmission at intervals not exceeding 60 seconds until the initiating device is returned to its non-alarm condition (per NFPA 72, Chapter 6, Section 6.16.3.2). The smoke alarm shall have remote hush and low battery hush capabilities. The unit shall have alarm memory to indicate which alarm in a system was the initiating alarm (per NFPA 72, Chapter 6, Section 6.16.3.5). The unit shall provide optional tamper resistance that deters removal of the unit from the wall or ceiling. The alarm shall include a test button that will electronically simulate the presence of smoke and cause the unit to go into alarm. This sequence tests the unit’s electronics, battery and horn to ensure proper operation. The unit shall include a piezoelectric horn that is rated at 85 decibels at 10 feet. The smoke alarm shall produce an audible signal in the form of the “three pulse” temporal pattern. Each ON phase shall last 0.5-second +/-10 percent. After the third of these ON phases, there shall be an OFF phase that lasts 1.5 seconds +/-10 percent. This pattern should repeat continuously without interruption. The unit shall also include a low battery warning utilizing a brief alarm chirp every 30-40 seconds for a minimum of seven (7) days. The unit shall incorporate one red LED to indicate the alarm’s current status and mode of operation. The red LED will flash in conjunction with the alarm beep, and flash during a smoke alarm, a low battery mode and a unit error. The unit shall incorporate one green LED to indicate the alarm’s current status and mode of operation. The green LED will indicate one of four (4) conditions: Standby Condition – The LED will flash approximately every 10 seconds. Initiating Alarm Indicator – The LED will flash every second while sounding an alarm to signify that the alarm sensed a smoke hazard. Alarm Memory Condition – The LED will flash every second signifying that the alarm sensed a smoke hazard. It will continue to flash every second until the test/reset button is pressed, thus resetting the alarm. Hush® Mode Condition – The LED will flash every 2 seconds while the alarm is in Hush® Mode The unit shall at a minimum meet the requirements of UL217, NFPA72 (chapter 11 2002 edition), The State of California Fire Marshall, NFPA 101 (one and two family dwellings) Federal Housing Authority (FHA), Housing and Urban Development (HUD). It shall also include a 10-year manufacturer’s limited warranty.