Share:
Spectrex 40/40D Series
The SharpEye next generation 40/40D series features ultra fast fastest detection of hydrocarbon-based fuel and gas fires at the longest distance at up to 300 ft. (90 m) using pioneering QuadSense technology - the next step in the optical flame detection industry with best-in-class performance and reliability.
The series is suited to meet the challenges of any high-risk industrial application with revolutionary UV/IR BIT and smart field of view optical integrity for flawless operation, widest operation temperature range in extreme weather conditions providing trustworthy protection of major value property and personnel to keep a SharpEye on your safety.
- Fastest response to fire
- Longest distance detection, revolutionary UV/IR technology
- Extended detection range increases the detection coverage by >2 times
- High sensitivity
- Superior immunity to false alarms
- Functioning in harsh conditions
- Unparalleled reliability and durability
- Improved design
- Easy to install and maintain
- Universal wiring options
- Multiple output options for maximum flexibility and compatibility
- Ensuring flawless operation
- Suited to meet the challenges of wide range and commercial applications
- Providing superior protection of high value property and personnel
Detection Range
- 40/40D-I: 90m
- 40/40D-M: 90m
- 40/40D-LB: 28m
- 40/40D-L4B: 28m
Coverage Area - square metres
- 40/40D-I: 6336
- 40/40D-M: 5426
- 40/40D-LB: 641
- 40/40D-L4B: 641
Coverage Area - cubic metres
- 40/40D-I: 446357
- 40/40D-M: 321832
- 40/40D-LB: 13356
- 40/40D-L4B: 13356
Standard Response Time
- 40/40D-I: Typically <2 sec at 40m
- 40/40D-M: Typically <2 sec at 40m
- 40/40D-LB: Typically 5 sec at 28m
- 40/40D-L4B: Typically 5 sec at 28m
Ultra Fast Response Time
- 40/40D-I: Typically <1 sec at 30m
- 40/40D-M: Typically <1 sec at 30m
- 40/40D-LB: 20 msec for flash fire pan fire from 3m distance via analog voltage output
- 40/40D-L4B: 20 msec for flash fire pan fire from 3m distance
High Speed Response Time (explosion)
- 40/40D-I: 50 msec for 1ft diameter sphere LPG-air mixture explosion at 20m via analog voltage output
- 40/40D-M: 50 msec for 1ft diameter sphere LPG-air mixture explosion at 20m via analog voltage output
- 40/40D-LB: 50 msec for 1 ft diameter sphere LPG-air mixture explosion at 10m via analog voltage output
- 40/40D-L4B: 50 msec for 1 ft diameter sphere LPG-air mixture explosion at 10m via analog voltage output
No. of Sensitivities Options
- 40/40D-I: 6
- 40/40D-M: 6
- 40/40D-LB: 3
- 40/40D-L4B: 3
Field of View
- 40/40D-I: Horizontal 100°; Vertical 95°
- 40/40D-M: Horizontal 80°; Vertical 80° - for Gasoline Horizontal 90°; Vertical 90° - for Hydrogen
- 40/40D-LB: Horizontal 100°; Vertical 95°
- 40/40D-L4B: Horizontal 100°; Vertical 95°
Built-In-Test
- 40/40D-I: IR
- 40/40D-M: IR
- 40/40D-LB: UV & IR
- 40/40D-L4B: UV & IR
Temperature Range
- 40/40D-I: -60 °C to +85 °C
- 40/40D-M: -60 °C to +85 °C
- 40/40D-LB: -60 °C to +85 °C
- 40/40D-L4B: -60 °C to +85 °C
Detects
- 40/40D-I: Hydrocarbon fires
- 40/40D-M: Hydrogen and hydrocarbon fires
- 40/40D-LB: Hydrocarbon-based fuel and gas, hydroxyl, hydrogen, metal, inorganic, etc.
- 40/40D-L4B: Hydrocarbon-based fuel and gas fires
- Fastest response to fire
- Longest distance detection, revolutionary UV/IR technology
- Extended detection range increases the detection coverage by >2 times
- High sensitivity
- Superior immunity to false alarms
- Functioning in harsh conditions
- Unparalleled reliability and durability
- Improved design
- Easy to install and maintain
- Universal wiring options
- Multiple output options for maximum flexibility and compatibility
- Ensuring flawless operation
- Suited to meet the challenges of wide range and commercial applications
- Providing superior protection of high value property and personnel
Detection Range
- 40/40D-I: 90m
- 40/40D-M: 90m
- 40/40D-LB: 28m
- 40/40D-L4B: 28m
Coverage Area - square metres
- 40/40D-I: 6336
- 40/40D-M: 5426
- 40/40D-LB: 641
- 40/40D-L4B: 641
Coverage Area - cubic metres
- 40/40D-I: 446357
- 40/40D-M: 321832
- 40/40D-LB: 13356
- 40/40D-L4B: 13356
Standard Response Time
- 40/40D-I: Typically <2 sec at 40m
- 40/40D-M: Typically <2 sec at 40m
- 40/40D-LB: Typically 5 sec at 28m
- 40/40D-L4B: Typically 5 sec at 28m
Ultra Fast Response Time
- 40/40D-I: Typically <1 sec at 30m
- 40/40D-M: Typically <1 sec at 30m
- 40/40D-LB: 20 msec for flash fire pan fire from 3m distance via analog voltage output
- 40/40D-L4B: 20 msec for flash fire pan fire from 3m distance
High Speed Response Time (explosion)
- 40/40D-I: 50 msec for 1ft diameter sphere LPG-air mixture explosion at 20m via analog voltage output
- 40/40D-M: 50 msec for 1ft diameter sphere LPG-air mixture explosion at 20m via analog voltage output
- 40/40D-LB: 50 msec for 1 ft diameter sphere LPG-air mixture explosion at 10m via analog voltage output
- 40/40D-L4B: 50 msec for 1 ft diameter sphere LPG-air mixture explosion at 10m via analog voltage output
No. of Sensitivities Options
- 40/40D-I: 6
- 40/40D-M: 6
- 40/40D-LB: 3
- 40/40D-L4B: 3
Field of View
- 40/40D-I: Horizontal 100°; Vertical 95°
- 40/40D-M: Horizontal 80°; Vertical 80° - for Gasoline Horizontal 90°; Vertical 90° - for Hydrogen
- 40/40D-LB: Horizontal 100°; Vertical 95°
- 40/40D-L4B: Horizontal 100°; Vertical 95°
Built-In-Test
- 40/40D-I: IR
- 40/40D-M: IR
- 40/40D-LB: UV & IR
- 40/40D-L4B: UV & IR
Temperature Range
- 40/40D-I: -60 °C to +85 °C
- 40/40D-M: -60 °C to +85 °C
- 40/40D-LB: -60 °C to +85 °C
- 40/40D-L4B: -60 °C to +85 °C
Detects
- 40/40D-I: Hydrocarbon fires
- 40/40D-M: Hydrogen and hydrocarbon fires
- 40/40D-LB: Hydrocarbon-based fuel and gas, hydroxyl, hydrogen, metal, inorganic, etc.
- 40/40D-L4B: Hydrocarbon-based fuel and gas fires