Share:
X5200 Ultraviolet Infrared Flame Detector
The X5200 UVIR hydrocarbon flame detector can be configured to satisfy third-party requirements for rapid detection or for applications where extraneous IR radiation sources may cause other detectors to generate false alarms.
- Multiple sensitivity modes
- Optical Integrity (oi®) performs automatic fail-safe checks every 60 seconds
- Heated optics for adverse environments and weather
- Data logger with event time and date stamping (1500 events)
- Can be configured to alarm to individual UV or IR sources
- Can meet NFPA 15 Ultra-High-Speed requirements (when properly configured and used in an EQP/HSDM safety system)
- Operating Voltage: 24 Vdc. Operating range is 18 to 30 Vdc, Maximum ripple is 2 volts peak-to-peak.
- Power Consumption: 2.8 watts @ 24 Vdc nominal; 17.5 watts @ 30 Vdc with EOL resistor installed and heater on maximum.
- Relays: Contacts rated 5 amperes at 30 Vdc.
Fire Alarm: Form C (NO and NC contacts); normally de-energised: latching/non-latching
Fault: Form A (NO contacts); normally energszed; latching/non-latching
Auxiliary*: Form C (NO and NC contacts); normally energised; latching/non-latching. - Current Output*: 0–20 mA (± 0.3 mA), with a maximum loop resistance of 500 ohms from 18–19.9 Vdc, 600 ohms from 20–30 Vdc.
- Temperature Range:
Operating: –40°C to +75°C
Storage: –55°C to +85°C
Hazardous location ratings: –55°C to +75°C
available on flameproof model - Humidity Range: 0 to 95% relative humidity, can withstand 100% condensing humidity for short periods of time.
- Spectral Sensitivity Range: All X5200 IR wavelength range 4-5 microns. X5200/ X5200G UV wavelength range 185-245 nanometers X5200M UV wavelength range 185-265 nanometers.
- Field of View: The detector has a 90 degree cone of vision (horizontal) with the highest sensitivity lying along its central axis.
- Source Tube: Contains radioactive isotope Krypton 85 (Kr85) Calculated Activity: 14,800 Becquerels (0.4μCi) Note: Not applicable to model X2200G.
- Warranty: 3 years.
- Enclosure Material: Copper-free aluminum (painted) or stainless steel (316/CF8M cast)..
- Conduit Entry Size: 3/4 inch NPT or M25.
- Wiring: 16 AWG or 2.5 mm2 shielded cable is recommended.
- Shipping Weight:
Aluminum: 3.2 kg
Stainless Steel: 6.7 kg
- FM Approved
- IEC 61508
- VNIIFTRI
- VNIIPO
- DEMKO 01 ATEX 132195X
- IECEx
- UL-BR 17.0216X
- Multiple sensitivity modes
- Optical Integrity (oi®) performs automatic fail-safe checks every 60 seconds
- Heated optics for adverse environments and weather
- Data logger with event time and date stamping (1500 events)
- Can be configured to alarm to individual UV or IR sources
- Can meet NFPA 15 Ultra-High-Speed requirements (when properly configured and used in an EQP/HSDM safety system)
- Operating Voltage: 24 Vdc. Operating range is 18 to 30 Vdc, Maximum ripple is 2 volts peak-to-peak.
- Power Consumption: 2.8 watts @ 24 Vdc nominal; 17.5 watts @ 30 Vdc with EOL resistor installed and heater on maximum.
- Relays: Contacts rated 5 amperes at 30 Vdc.
Fire Alarm: Form C (NO and NC contacts); normally de-energised: latching/non-latching
Fault: Form A (NO contacts); normally energszed; latching/non-latching
Auxiliary*: Form C (NO and NC contacts); normally energised; latching/non-latching. - Current Output*: 0–20 mA (± 0.3 mA), with a maximum loop resistance of 500 ohms from 18–19.9 Vdc, 600 ohms from 20–30 Vdc.
- Temperature Range:
Operating: –40°C to +75°C
Storage: –55°C to +85°C
Hazardous location ratings: –55°C to +75°C
available on flameproof model - Humidity Range: 0 to 95% relative humidity, can withstand 100% condensing humidity for short periods of time.
- Spectral Sensitivity Range: All X5200 IR wavelength range 4-5 microns. X5200/ X5200G UV wavelength range 185-245 nanometers X5200M UV wavelength range 185-265 nanometers.
- Field of View: The detector has a 90 degree cone of vision (horizontal) with the highest sensitivity lying along its central axis.
- Source Tube: Contains radioactive isotope Krypton 85 (Kr85) Calculated Activity: 14,800 Becquerels (0.4μCi) Note: Not applicable to model X2200G.
- Warranty: 3 years.
- Enclosure Material: Copper-free aluminum (painted) or stainless steel (316/CF8M cast)..
- Conduit Entry Size: 3/4 inch NPT or M25.
- Wiring: 16 AWG or 2.5 mm2 shielded cable is recommended.
- Shipping Weight:
Aluminum: 3.2 kg
Stainless Steel: 6.7 kg
- FM Approved
- IEC 61508
- VNIIFTRI
- VNIIPO
- DEMKO 01 ATEX 132195X
- IECEx
- UL-BR 17.0216X