The Signature Series SIGA-PDI optical smoke detector brings advanced sensing technology to a practical design that increases efficiency, saves installation time, cuts costs, and extends life safety and property protection capabilities.
- Next generation Optical Smoke Sensing Technology
- 0.05 db/m to 0.30 db/m obscuration (Band 1)
- Uses existing wiring
- Automatic device mapping
- Up To 250 total signature addresses per loop
- Two levels of environmental compensation
- Two levels of dirty detector warning
- Twenty pre-alarm settings
- Five sensitivity settings
- Non-volatile memory
- Electronic addressing
- Identification of dirty or defective detectors
- Automatic day/night sensitivity adjustment
- Bicolour (green/red) status LED
- Standard, relay, fault isolator, and audible mounting bases
- Sensor markings provide easy testing identification
- Operating voltage: 15.20 to 19.95 VDC
- Normal operating current: 51
- Alarm current: 68
- Smoke Sensitivity Range: 0.05 db/m to 0.30 db/m obscuration (Band 1)
- Vibration level: 10 to 35 Hz, with an amplitude of 0.01in.
- Air velocity: 0 to 20 m/s (0 to 4,000 ft./min)
- Wall mounting: 305 mm max. from ceiling
- Compatible bases: See ordering information
- Compatible detector testers: Testifire 1000, Testifire 2000
- Operating environment: -100 C to 550 C, 0 to 93% RH, noncondensing
- Construction: High impact engineering polymer, white
- Storage temperature: -20 to 600
- Environmental compensation: Automatic
- Continuous self-diagnostics ensure reliability over the long-haul, while environmental compensation helps reduce maintenance costs
- ActivFire
- UL
- ULC
- MEA
- CSFM
- FM
- EN54-7:2000, AS 7240.7
- Next generation Optical Smoke Sensing Technology
- 0.05 db/m to 0.30 db/m obscuration (Band 1)
- Uses existing wiring
- Automatic device mapping
- Up To 250 total signature addresses per loop
- Two levels of environmental compensation
- Two levels of dirty detector warning
- Twenty pre-alarm settings
- Five sensitivity settings
- Non-volatile memory
- Electronic addressing
- Identification of dirty or defective detectors
- Automatic day/night sensitivity adjustment
- Bicolour (green/red) status LED
- Standard, relay, fault isolator, and audible mounting bases
- Sensor markings provide easy testing identification
- Operating voltage: 15.20 to 19.95 VDC
- Normal operating current: 51
- Alarm current: 68
- Smoke Sensitivity Range: 0.05 db/m to 0.30 db/m obscuration (Band 1)
- Vibration level: 10 to 35 Hz, with an amplitude of 0.01in.
- Air velocity: 0 to 20 m/s (0 to 4,000 ft./min)
- Wall mounting: 305 mm max. from ceiling
- Compatible bases: See ordering information
- Compatible detector testers: Testifire 1000, Testifire 2000
- Operating environment: -100 C to 550 C, 0 to 93% RH, noncondensing
- Construction: High impact engineering polymer, white
- Storage temperature: -20 to 600
- Environmental compensation: Automatic
- Continuous self-diagnostics ensure reliability over the long-haul, while environmental compensation helps reduce maintenance costs
- ActivFire
- UL
- ULC
- MEA
- CSFM
- FM
- EN54-7:2000, AS 7240.7