Conventional Rate of Rise and Fixed Temperature Heat Detector
DC-9103E-KID is the new Generation of Conventional Rate of Rise and Fixed Temperature Heat from KIDDE. The DC series Detectors have a microprocessor and use Advanced Algorithms to reliably Detect Fire alarm conditions.
By Default, the DC-9103E-KID is supplied as an A1R class Heat Detector. Using the Handheld Programmer, the installer can easily program the device as an A2S or BS Detector without the need to carry 3 different heat detectors to a site.
- 3 classes programmable.
- Magnetic test function.
- Output terminal for remote indicator.
- Complying with AS7240.5
- Operating Voltage: 24VDC(16VDC~28VDC).
- Standby Current: ≤60μA.
- Alarm Current: ≤55mA.
- Fire LED: Red, periodically flash once in polling when the status is set to “ON”; no illumination when the status is set to “OFF”. Periodically flash twice in fault; steady illumination when in alarm.
- Remote Indication Output: Polarity-sensitive, directly connecting with remote indicator (built in 10k resistor in series, maximum output current is 2.0mA).
- The remote indicator does not illuminate in normal and flashes in alarm: 2V (peak to peak value).
- Class and Setup: Classes A1R, A2S, BS programmable.
- Maximum Ripple Voltage: 2V ( peak-to-peak).
- Alarm Reset: Instantaneous cut-out (10s Min, 1.0VDCMax.).
- Wiring: Polarized two wire.
- Ingress Protection Rating: IP2X.
- Ambient Temperature:
Class A1: -10oC~+50oC
Class A2: -10oC~+50oC
Class B: -10oC~+65oC. - Typical Fixed Temperature:
Class A1: 58oC
Class A2: 62oC
Class B: 77oC. - Relative Humidity: ≤95%, non-condensing.
- Material: ABS.
- Dimensions:
Diameter: 100mm
Height: 53.3mm (with base). - Mounting Hole Spacing: 45mm~75mm.
- Weight: About 110g (with base).
- 3 classes programmable.
- Magnetic test function.
- Output terminal for remote indicator.
- Complying with AS7240.5
- Operating Voltage: 24VDC(16VDC~28VDC).
- Standby Current: ≤60μA.
- Alarm Current: ≤55mA.
- Fire LED: Red, periodically flash once in polling when the status is set to “ON”; no illumination when the status is set to “OFF”. Periodically flash twice in fault; steady illumination when in alarm.
- Remote Indication Output: Polarity-sensitive, directly connecting with remote indicator (built in 10k resistor in series, maximum output current is 2.0mA).
- The remote indicator does not illuminate in normal and flashes in alarm: 2V (peak to peak value).
- Class and Setup: Classes A1R, A2S, BS programmable.
- Maximum Ripple Voltage: 2V ( peak-to-peak).
- Alarm Reset: Instantaneous cut-out (10s Min, 1.0VDCMax.).
- Wiring: Polarized two wire.
- Ingress Protection Rating: IP2X.
- Ambient Temperature:
Class A1: -10oC~+50oC
Class A2: -10oC~+50oC
Class B: -10oC~+65oC. - Typical Fixed Temperature:
Class A1: 58oC
Class A2: 62oC
Class B: 77oC. - Relative Humidity: ≤95%, non-condensing.
- Material: ABS.
- Dimensions:
Diameter: 100mm
Height: 53.3mm (with base). - Mounting Hole Spacing: 45mm~75mm.
- Weight: About 110g (with base).