Skip to main content
Share:

VESDA-E VES Aspirating Smoke Detector


The VESDA-E VES can identify and monitor smoke density by individual sampling pipe (sector) which allows a single zone to be divided into four separate sectors; for example, distinguishing between separate aisles within a data room. Sector addressability enables the user to respond to a potential fire event quickly by reducing the search area. The VESDA-E VES has four programable alarm thresholds (Alert, Action, Fire 1 and Fire 2) per pipe that allows flexible field application. After the detector identifies the first sector to reach the Alert threshold it continues to sample from all sectors to report real time status per sector via the intuitive touch screen display. Built on the Flair detection technology and years of application experience the VESDA-E VES detector delivers very early warning with the best in class dust rejection throughout its lifetime.
  • Sector addressability for up to four sectors
  • Adaptive scan threshold
  • Flair detection technology delivers reliable very early warning in a wide range of environments with minimal nuisance alarms
  • Multi stage filtration and optical protection with clean air barriers ensures lifetime detection performance
  • Four configurable alarm levels per sector and a wide sensitivity range deliver optimum protection for the widest range of applications
  • Intuitive LCD display provides instant status information for immediate response
  • Flow fault thresholds per port accommodate varying airflow conditions
  • Smart on-board filter retains dust count and remaining filter life for predictable maintenance
  • Extensive event log (20,000 events) for event analysis and system diagnostics
  • AutoLearn™ smoke and flow for reliable and rapid commissioning
  • Backward compatible with VLS and VESDAnet
  • Ethernet for connectivity with Xtralis software for configuration, secondary monitoring and maintenance
  • USB for PC configuration, and firmware upgrade using a memory stick
  • Two programmable GPIs (1 monitored) for flexible remote control
  • Field replaceable sub-assemblies enable faster service and maximum uptime
  • Supply Voltage: 18-30 VDC (24 V Nominal)
  • Power Consumption @ 24VDC (VES-A00-P):
    Aspirator Setting: 1; 5; 10 
    Power (Quiescent): 7.9 W; 9.7 W; 14.8 W
    Power (In Alarm): 8.5 W; 9.9 W; 14.5 W
  • Power Consumption @ 24VDC (VES-A10-P)
    Aspirator Setting: 1; 5; 10 
    Power (Quiescent): 8.6 W; 10.5 W; 15.4 W 
    Power (In Alarm): 9.4 W; 10.8 W; 15.2 W
  • Dimensions (WHD): 350mm x 225mm x 135mm
  • Weight: 
    VES-A00-P: 4.7kg
    VES-A10-P: 4.8kg
  • Operating Conditions: 
    Ambient: 0°C to 39°C
    * Tested to (EN54-20): -10°C to 55°C
    Sampled Air: -20°C to 60°C
    ** Humidity: 5% to 95% RH, non-condensing
  • Area Coverage: 2,000m2
  • Min. airflow per pipe: 20 l/m
  • Pipe Length (Linear): 280m
  • Pipe Length (Branched): 56m
  • Pipe lengths depending on number of pipes in use: 
    2 Pipes: 100m
    3 Pipes: 80m
    4 pipes: 70m
  • No. of holes (A/B/C): 40/80/100***
  • Computer design tool: ASPIRE
  • Pipe: Inlet: External diameter 25mm or 1.05in (3/4 in IPS) Exhaust: External diameter 25mm or 1.05in (3/4 in IPS) via adaptor
  • Relays: 12 programmable relays (latching or non-latching states) Contacts rated 2 A @ 30 VDC (Resistive)
  • IP rating: IP40
  • Cable access: 4 x 26 mm cable entries
  • Cable termination: Screw Terminal blocks 0.2–2.5 sq mm (24–14 AWG)
  • Dynamic Range: 0.000%/m to 32%/m
  • Sensitivity Range: 0.005 to 20% obs/m
  • Threshold setting range: 
    Alert: 0.005% to 2.0% obs/m
    Action: 0.005% to 2.0% obs/m
    Fire1: 0.010% to 2.0% obs/m 
    Fire2: 0.020% to 20.0% obs/m
  • Software features: 
    Event log: Up to 20,000 events Smoke level and alarm threshold levels, user actions, alarms and faults with time and date stamp
    AutoLearn: Detector learns Alarm Thresholds and Flow Fault thresholds by monitoring the environment
  • UL
  • ULC
  • CSFM
  • ActivFire
  • VdS
  • EN 54-20, ISO 7240-20
    Class A: (40 holes / Fire 1 = 0.067% obs/m)
    Class B: (80 holes / Fire 1 = 0.085% obs/m)
    Class C: (100 holes / Fire 1 = 0.251% obs/m)
    Classification of any configuration is determined using ASPIRE.
  • Sector addressability for up to four sectors
  • Adaptive scan threshold
  • Flair detection technology delivers reliable very early warning in a wide range of environments with minimal nuisance alarms
  • Multi stage filtration and optical protection with clean air barriers ensures lifetime detection performance
  • Four configurable alarm levels per sector and a wide sensitivity range deliver optimum protection for the widest range of applications
  • Intuitive LCD display provides instant status information for immediate response
  • Flow fault thresholds per port accommodate varying airflow conditions
  • Smart on-board filter retains dust count and remaining filter life for predictable maintenance
  • Extensive event log (20,000 events) for event analysis and system diagnostics
  • AutoLearn™ smoke and flow for reliable and rapid commissioning
  • Backward compatible with VLS and VESDAnet
  • Ethernet for connectivity with Xtralis software for configuration, secondary monitoring and maintenance
  • USB for PC configuration, and firmware upgrade using a memory stick
  • Two programmable GPIs (1 monitored) for flexible remote control
  • Field replaceable sub-assemblies enable faster service and maximum uptime
  • Supply Voltage: 18-30 VDC (24 V Nominal)
  • Power Consumption @ 24VDC (VES-A00-P):
    Aspirator Setting: 1; 5; 10 
    Power (Quiescent): 7.9 W; 9.7 W; 14.8 W
    Power (In Alarm): 8.5 W; 9.9 W; 14.5 W
  • Power Consumption @ 24VDC (VES-A10-P)
    Aspirator Setting: 1; 5; 10 
    Power (Quiescent): 8.6 W; 10.5 W; 15.4 W 
    Power (In Alarm): 9.4 W; 10.8 W; 15.2 W
  • Dimensions (WHD): 350mm x 225mm x 135mm
  • Weight: 
    VES-A00-P: 4.7kg
    VES-A10-P: 4.8kg
  • Operating Conditions: 
    Ambient: 0°C to 39°C
    * Tested to (EN54-20): -10°C to 55°C
    Sampled Air: -20°C to 60°C
    ** Humidity: 5% to 95% RH, non-condensing
  • Area Coverage: 2,000m2
  • Min. airflow per pipe: 20 l/m
  • Pipe Length (Linear): 280m
  • Pipe Length (Branched): 56m
  • Pipe lengths depending on number of pipes in use: 
    2 Pipes: 100m
    3 Pipes: 80m
    4 pipes: 70m
  • No. of holes (A/B/C): 40/80/100***
  • Computer design tool: ASPIRE
  • Pipe: Inlet: External diameter 25mm or 1.05in (3/4 in IPS) Exhaust: External diameter 25mm or 1.05in (3/4 in IPS) via adaptor
  • Relays: 12 programmable relays (latching or non-latching states) Contacts rated 2 A @ 30 VDC (Resistive)
  • IP rating: IP40
  • Cable access: 4 x 26 mm cable entries
  • Cable termination: Screw Terminal blocks 0.2–2.5 sq mm (24–14 AWG)
  • Dynamic Range: 0.000%/m to 32%/m
  • Sensitivity Range: 0.005 to 20% obs/m
  • Threshold setting range: 
    Alert: 0.005% to 2.0% obs/m
    Action: 0.005% to 2.0% obs/m
    Fire1: 0.010% to 2.0% obs/m 
    Fire2: 0.020% to 20.0% obs/m
  • Software features: 
    Event log: Up to 20,000 events Smoke level and alarm threshold levels, user actions, alarms and faults with time and date stamp
    AutoLearn: Detector learns Alarm Thresholds and Flow Fault thresholds by monitoring the environment
  • UL
  • ULC
  • CSFM
  • ActivFire
  • VdS
  • EN 54-20, ISO 7240-20
    Class A: (40 holes / Fire 1 = 0.067% obs/m)
    Class B: (80 holes / Fire 1 = 0.085% obs/m)
    Class C: (100 holes / Fire 1 = 0.251% obs/m)
    Classification of any configuration is determined using ASPIRE.