Skip to main content

Kidde Hallway Battery Operated Smoke Alarm
i9080


Ideal for hallways with emergency safety light to guide you to safety

  • Safety Light – Illuminates when alarm sounds to guide your way to safety.

  • Hush® Feature – Temporarily silences nuisance alarms.

  • Part #: 0918

Power Source
Battery
Sensor
Ionization
Safety Features
Better

The Kidde i9080 is a battery operated, ionization smoke alarm with a safety light that helps guide your way to safety. This unit is designed to alert you and your family to the dangers of smoke and fire. The i9080 includes a 9V battery that powers the smoke alarm, along with an additional 9V battery to power the safety light. This easy to install smoke alarm is UL Listed and offers a 5-year limited warranty.

Benefits

The Kidde i9080 battery operated smoke alarm with a safety light provides you and your family an early warning signal in the event of a smoke or fire incident. The illumination of the safety light helps guide your way to safety when dense smoke is present. The i9080 includes a Hush® feature that temporarily silences nuisance alarms along with a test button that allows you to test the alarm’s electronic circuitry, horn and battery function.

This smoke alarm is particularly useful in hallways and near exits. This alarm uses ionization sensing technology. Ionization sensing alarms may detect invisible fire particles (associated with flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible particles (associated with smoldering fires) sooner than ionization alarms. Kidde strongly recommends that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fire that can occur within the home.

Part Number(Ordering Number):0918

  • Safety Light – Illuminates when alarm sounds to guide your way to safety.

  • Hush® Feature – Temporarily silences nuisance alarms.

  • Red LED – Flashes every 30-40 seconds to indicate that the smoke alarm is operating.

  • Test Button – Tests unit’s electronic circuitry, horn, safety light, and battery function.

  • Battery Operated (Includes 2 9V batteries) – Protects even during power outages.

  • Tamper Resist Locking Pin – Helps deter from theft or tampering.

  • Low Battery Indicator – Smoke alarm will chirp in the event of a low battery.

Technical Specifications

Model: i9080
Power Source: Two (2) 9V Batteries (included)
Audio Alarm: 85dB at 10ft
Temperature Range: 40˚F to 100˚F (4˚C to 38˚C)
Humidity Range: up to 85% relative humidity (RH)
Sensor: Ionization
Size: 5” in diameter x 1.5” depth
Weight: 1lb
Interconnects: No
LED: Red, normal operation
Warranty: 10 year limited


i9080-Technical-Diagram

Architectural and Engineering Specifications

The smoke alarm shall be Kidde Model i9080 or approved equal. It shall be powered by a 9V battery. The unit shall incorporate an ionization sensor with nominal sensitivity of 0.58-1.31%/ft. The temperature operation range shall be between 40°F and 100°F (4°C and 38°C) and the humidity operation range shall be up to 85% relative humidity. The unit shall provide optional tamper resistance that helps deter removal of the unit from the wall or ceiling. The alarm shall include a safety light that shall be powered by a 9V alkaline battery. The safety light shall provide 15 minutes of light when the alarm is sounding. The alarm shall include a test button that will electronically simulate the presence of smoke and cause the unit to go into alarm. This sequence tests the unit’s electronics, battery, safety light and horn to ensure proper operation. The unit shall also include a low battery warning utilizing a brief alarm chirp every 30-40 seconds along brief flashed from the safety light for a minimum of seven (7) days. The unit shall incorporate one red LED to indicate the alarm’s current status and mode of operation. The red LED will indicate one of two conditions: Standby Condition: The red LED will flash every 30-40 seconds to indicate that the smoke alarm is operating properly. Alarm Condition: When the alarm senses products of combustion and goes into alarm, the red LED will flash rapidly (one flash per second). The rapid flashing LED and pulsating alarm will continue until the air is cleared. The unit shall at a minimum meet the requirements of UL217, NFPA72, (chapter 11 2002 edition), The State of California Fire Marshall, NFPA 101 (One and two family dwellings) Federal Housing Authority (FHA), Housing and Urban Development (HUD).

The Kidde i9080 is a battery operated, ionization smoke alarm with a safety light that helps guide your way to safety. This unit is designed to alert you and your family to the dangers of smoke and fire. The i9080 includes a 9V battery that powers the smoke alarm, along with an additional 9V battery to power the safety light. This easy to install smoke alarm is UL Listed and offers a 5-year limited warranty.

Benefits

The Kidde i9080 battery operated smoke alarm with a safety light provides you and your family an early warning signal in the event of a smoke or fire incident. The illumination of the safety light helps guide your way to safety when dense smoke is present. The i9080 includes a Hush® feature that temporarily silences nuisance alarms along with a test button that allows you to test the alarm’s electronic circuitry, horn and battery function.

This smoke alarm is particularly useful in hallways and near exits. This alarm uses ionization sensing technology. Ionization sensing alarms may detect invisible fire particles (associated with flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible particles (associated with smoldering fires) sooner than ionization alarms. Kidde strongly recommends that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fire that can occur within the home.

Part Number(Ordering Number):0918

  • Safety Light – Illuminates when alarm sounds to guide your way to safety.

  • Hush® Feature – Temporarily silences nuisance alarms.

  • Red LED – Flashes every 30-40 seconds to indicate that the smoke alarm is operating.

  • Test Button – Tests unit’s electronic circuitry, horn, safety light, and battery function.

  • Battery Operated (Includes 2 9V batteries) – Protects even during power outages.

  • Tamper Resist Locking Pin – Helps deter from theft or tampering.

  • Low Battery Indicator – Smoke alarm will chirp in the event of a low battery.

Technical Specifications

Model: i9080
Power Source: Two (2) 9V Batteries (included)
Audio Alarm: 85dB at 10ft
Temperature Range: 40˚F to 100˚F (4˚C to 38˚C)
Humidity Range: up to 85% relative humidity (RH)
Sensor: Ionization
Size: 5” in diameter x 1.5” depth
Weight: 1lb
Interconnects: No
LED: Red, normal operation
Warranty: 10 year limited


i9080-Technical-Diagram

Architectural and Engineering Specifications

The smoke alarm shall be Kidde Model i9080 or approved equal. It shall be powered by a 9V battery. The unit shall incorporate an ionization sensor with nominal sensitivity of 0.58-1.31%/ft. The temperature operation range shall be between 40°F and 100°F (4°C and 38°C) and the humidity operation range shall be up to 85% relative humidity. The unit shall provide optional tamper resistance that helps deter removal of the unit from the wall or ceiling. The alarm shall include a safety light that shall be powered by a 9V alkaline battery. The safety light shall provide 15 minutes of light when the alarm is sounding. The alarm shall include a test button that will electronically simulate the presence of smoke and cause the unit to go into alarm. This sequence tests the unit’s electronics, battery, safety light and horn to ensure proper operation. The unit shall also include a low battery warning utilizing a brief alarm chirp every 30-40 seconds along brief flashed from the safety light for a minimum of seven (7) days. The unit shall incorporate one red LED to indicate the alarm’s current status and mode of operation. The red LED will indicate one of two conditions: Standby Condition: The red LED will flash every 30-40 seconds to indicate that the smoke alarm is operating properly. Alarm Condition: When the alarm senses products of combustion and goes into alarm, the red LED will flash rapidly (one flash per second). The rapid flashing LED and pulsating alarm will continue until the air is cleared. The unit shall at a minimum meet the requirements of UL217, NFPA72, (chapter 11 2002 edition), The State of California Fire Marshall, NFPA 101 (One and two family dwellings) Federal Housing Authority (FHA), Housing and Urban Development (HUD).

26
The Kidde App
Compatible with Google Home and Alexa. Use voice commands to
check alarm status and connection.

Google Home is a registered trademark of Google LLC. Amazon, Alexa and all related logos are registered trademarks of Amazon Technologies, Inc.